EC-GDS3

Main specification

HeadingContents
LeadThread lead (mm)2
VerticalLoad capacityMaximum load capacity (kg)0.8
Speed/ Acceleration/DecelerationMaximum speed (mm/s)100
Minimum speed (mm/s)10
Rated acceleration/deceleration (G)0.3
Maximum acceleration/deceleration (G)0.3
Pressing motionMax. pressing thrust (N)17
Max. pressing speed (mm/s)20
BrakeBrake specificationNon-excitation electromagnetic brake
Brake retention force (kgf)0.8
StrokeMinimum stroke (mm)10
Maximum stroke (mm)30
Stroke pitch (mm)10

HeadingContents
Drive systemSliding screw φ4mm, rolled C10
Accuracy of Repeating Positioning.±0.05mm
Lost motion- (Can't be indicated because this is a 2-point positioning function. )
Non-rotational accuracy of rod
Guide rodSintered oil-impregnated bearing
Running life (Note 7)5 million vertical reciprocating movements
Ambient operating temperature and humidity0 - 40℃, RH 85% and below (no condensation)
Protection gradeIP20
Vibration resistant/Shock resistant4.9m/s2
Compatible to overseas standardsCE mark, RoHS compliant
Motor typePulse motor (φ20) (power capacity: Max. 1.1A)
Encoder typeIncremental
Encoder pulse No.32768 pulse/rev
DeliveryWritten in [Reference for delivery] section of the homepage

(Note 7) Running life varies depending on operating conditions, installation status and the lubrication.

Load capacity by speed and acceleration table

The base unit for load capacity is kilogram (kg).

OrientationVertical
SpeedAcceleration (G)
(mm/s)0.3
00.8
300.8
700.8
1000.8

Stroke and maximum speed

(Measured in mm/s)

Lead
(mm)
10
(mm)
20
(mm)
30
(mm)
2100

Adaptive controller

(Note) EC series has their controller built-in themselves. See page 2 769 for details of the built-in controller.

Oversea specification

Important notes on selection

(1) The payload capacity indicated in the "Main specifications" is the maximum value. Please refer to "Load capacity by speed and acceleration table" for further information.
(2) When performing push operation, please refer to the "Correlation diagram of push force and current limit value". Pressing force shown are their standard value. Refer page 1- 315 for important points to be taken note of.
(3) Requires extra care required depending on the mounting posture. Refer to page 1-307 for further details.

Return to the page top

Dimension drawing

ST: Stroke

M.E.: Mechanical end

S.E.: Stroke end

(Note) When returning to the home position, the rod moves to M.E. Please be careful of interference with surrounding objects.

(Note) Secure the cable so that the base of the cable does not move.

 Cables can be separated and replaced. (Connector connection inside cable box)

 The cable exit direction (optional) can be changed by changing the direction of the cable box.

Dimension by stroke length

Stroke102030
L
(Note 8)
Without brake97107117
With brake122132142
B283848
C102030
F01020
H244
J01020

(Note 8) If you select the cable exit direction (optional), the dimensions will be subtracted by 1.

Mass by stroke length

Stroke102030
Mass
(kg)
Without brake0.150.170.19
With brake0.170.190.21

Correlation diagram of work mass and work collision speed

(*1) When using, please ensure that the length of L is 50mm or less.

(*2) Thrust from conveyors, etc. must be limited to the "allowable lateral load" or less.

Stroke102030
Allowable lateral load (N)7.27.76.9