IXA-4NSW3015

Main specification

HeadingContents
4-axis type
Maximum load capacity (kg) (Note 1)6
Speed
(Note 2)
Maximum resultant speed (mm/s)5126
Maximum speed of each axis1st arm (degree/s)690
2nd arm (degree/s)690
Vertical axis (mm/s)1500
Rotating axis (degree/s)1600
Push force (N) (Note 3)Upper limit98
Minimum23
Arm length (mm)300
Arm length of each axis (mm)1st arm155
2nd arm145
Operating range of each axis1st arm (degree)±121
2nd arm (degree)±125
Vertical axis (mm)150
Rotating axis (degree)±360

HeadingContents
4-axis type
Repeated positioning accuracy
(Note 4)
Horizontal plane±0.01mm
Vertical axis±0.01mm
Rotating shaft±0.005 degree
User wiring10-core (9-core + shield) AWG24 (Rated 30V / Max. 1A)
User pipingOuter diameter φ4 Inner diameter φ2.5 3 air tubes
(max. working pressure 0.6MPa)
Alarm indicator light (Note 5)Absent
Brake release switch (Note 6)Brake release switch for vertical axis fall prevention
Tip shaftAllowable torque4.5N・m
Allowable load moment7.1N・m
Main materialSee page 1-347.
Ambient operating temperature and humidity0-40℃, 20-85% RH or less (no condensation)
Protection gradeIP65 (excl. bellows)
Air purge pressure (Note 8)35kPa
Vibration resistant/Shock resistantNo shock or vibration
Noise (Note 7)80dB or less
Compatible to overseas standardsCE mark, RoHS compliant
Motor typeAC servo motor
Motor capacity1st arm600
2nd arm400
Vertical axis200
Rotating shaft100
Encoder typeBattery-less absolute
Encoder pulse No.16384 pulse/rev
DeliveryWritten in [Reference for delivery] section of the homepage

Important notes on selection

(1) For (Note 1) to (Note 9), refer to page 7-675.
(2) The maximum set value of acceleration / deceleration changes depending on the mass of the object to be transported, the moving distance, and the location. An overload error may occur if continuous operation was performed with the maximum set value. When performing continuous operation, lower the acceleration / deceleration value or set a stop time after acceleration / deceleration with reference to the duty (based on the guideline).
(3) Do not spray the bellows directly. Connect a Φ16 air tube to the bellows air supply/exhaust joint and open the tip to a clean space.
(4) SCARA robots cannot operate continuously at 100% speed and acceleration.
 Refer to "Guidelines for acceleration / deceleration settings" for the operating condition.

Return to the page top

Cycle time

HeadingTime
Standard Cycle Time0.38 sec
Continuous cycle time0.69 sec

The standard / continuous cycle time indicates the time required when operating with the fastest round-trip operation setting under the following conditions.

Transfer mass of 2kg, vertical movement of 25mm and horizontal movement of 300mm (coarse positioning arch motion)

[Standard cycle time]

The time required for the fastest operation. Generally, this is a guide for high-speed performance. Please note that continuous operation at the fastest operation is not possible.

[Continuous cycle time]

The cycle time for continuous operation.

Allowable load moment of inertia at the tip shaft

Number of axesAllowable load moment of inertia at the tip shaft
4-axis type0.12 kg・m2

During operation, use the following restrictions as a guide for the horizontal and vertical dimensions from the tip of the spline. If the load offset is large, it may cause abnormal noise or vibration, malfunction, or shorten the service life. Adjust the speed and acceleration / deceleration as appropriate, or adjust the balance of the center of gravity. The overhang length is limited based on the load and operating conditions.

Horizontal directionVertical direction
120mm or less100mm or less

Guideline for acceleration / deceleration setting

SCARA Robot IXA cannot operate continuously at the maximum acceleration / deceleration and maximum speed noted in the catalog. When operating at the maximum acceleration / deceleration, set the stop time by referring to the guideline graph of continuous operation duty. If continuous operation is required, operate it under a setting within the range indicated in the continuous operation guideline of the guideline graph for acceleration / deceleration setting.

(1) In case of PTP operation, be sure to use the WGHT instruction on the program to set the mass and moment of inertia before operating. For SCARA, 100% is defined as the maximum acceleration/deceleration that can be operated at each payload. Please note that the operating time varies based on payload even if the acceleration/deceleration and speed settings are the same.

(2) Adjust the acceleration / deceleration by gradually increasing the set value from the continuous operation guideline value.

(3) If an overload error occurs, reduce the acceleration / deceleration as appropriate, or make adjustments to set a stop time by referring to the guideline for continuous operation duty.

(4) Duty (%) = (Operating time / (Operating time + Stopping time)) x 100

(5) If you wish to move the robot horizontally at high speed, move the vertical axis as close to the rising end as possible.

(6) Keep the moment of inertia and payload below the allowable values.

(7) The payload indicates the moment of inertia and mass of the center of rotation of the 4th axis.

(8) Operate the robot with an appropriate acceleration / deceleration based on the mass and moment of inertia. Failure to comply will result in early life, damage and/or vibration of the drive unit.

(9) If the moment of inertia of the load is large, vibration may occur at the vertical axis depending on its position. If vibration occurs, slow down the acceleration / deceleration as appropriate.

PTP operation

CP operation

Horizontal

Vertical

CP operation speed / acceleration / deceleration limit

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork *Select
DVCCCIEPRCNMLML3ECEPPRTSSNECM
XSEL-RAX4/SAX4
(for IX, IXA)
4Three-phase AC200V36666
(depending on type)

(Note) Refer to page 8-17 for network abbreviations such as DV and CC.

Oversea specification

Dimension drawing

IXA-4NSW3015

ST: Stroke

M.E.: Mechanical end

S.E.: Stroke end

(Note) Please refer to pages 7-675 (Note 9) for details of the cable connection.

Mass

HeadingContents
Mass4-axis type48.0kg