IXP-3N2508
IXP-4N2508

Main specification

HeadingContents
3-axis type4-axis type3-axis specification
with medium gripper
(GM)
Maximum load capacity (kg) (Note1)30.5
Speed
(Note2)
Maximum resultant speed (mm/s)2151
Maximum speed of each axis1st arm (degree/s)325
2nd arm (degree/s)420
Vertical axis (mm/s)350
Rotating axis (degree/s)1200
Gripper (mm/s)94 (one finger)
Push force (N)Upper limitUnavailable
MinimumUnavailable
Arm length (mm)250
Arm length of each axis (mm)1st arm150
2nd arm100
Operating range of each axis1st arm (degree)±135
2nd arm (degree)±135
Vertical axis (mm)80
Rotating axis (degree)±360
Gripper (mm)14 (both fingers)

HeadingContents
3-axis type4-axis type3-axis specification
with medium gripper
(GM)
Repeated positioning accuracy
(Note3)
Horizontal plane±0.020 mm
Vertical axis±0.020 mm
Rotating shaft±0.010 degree
Gripper±0.010 mm
User wiring8-core AWG26 (Rated 30V/Max. 1A)
User pipingAir tube (O.D. ø4, I.D. ø2.5) x 2
(Maximum working pressure 0.8 MPa)
Alarm indicator lightAbsent
Brake release switchAbsent
Tip shaftAllowable torque0.28 N・m
Allowable load moment0.7 N・mMa,Mb,Mc:0.7N・m
Ambient operating temperature and humidityTemperature 0-40℃ Humidity 20-85% RH or less (no condensation)
Protection gradeIP20
Vibration resistant/Shock resistantNo shock or vibration
Noise (Note 4)75dB or less
Compatible to overseas standardsCE mark, RoHS compliant
Motor typePulse motor
Motor capacity1st arm
2nd arm
Vertical axis
Rotating shaft
Encoder typeBattery-less absolute
Encoder pulse number8192 pulse/rev 
DeliveryWritten in [Reference for delivery] section of the homepage

(Note) The gripper encoder is of an incremental specification with 800 pulse/rev.

Types of installed gripper

IXP-3N2508GMMedium gripper RCP4-GRSML installed at the tip of vertical axis

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork ※Select
DVCCCIEPRCNMLML3ECEPPRTSSNECM
MSEL-PCX/PGX4Single phase AC
100 - 230V
30000

(Note) Refer to page 7-17 for network abbreviation symbols such as DV and CC.

Cycle time

HeadingTime
Standard cycle time
Continuous cycle time
3-axis type0.79 sec
4-axis type0.79 sec
3-axis specification
with medium gripper (GM)
0.79 sec

The standard / continuous cycle time indicates the time required when operating with the fastest round-trip operation setting under the following conditions.

Transfer mass of 1kg, vertical movement of 25mm and horizontal movement of 300mm (coarse positioning arch motion)

The weight of the gripper is also included in the transport mass for the gripper installed specification.

The opening and closing time of the gripper is not included in the cycle time.

[Standard cycle time]

The time required for the fastest operation. Generally, this is a guide for high-speed performance.

[Continuous cycle time]

The cycle time for continuous operation.

Allowable load moment of inertia at the tip shaft

Number of axesAllowable load moment of inertia at the tip shaft
3-axis type0.01 kg・m2
4-axis type0.003 kg・m2
3-axis specification
with medium gripper (GM)
0.001 kg・m2

The allowable load moment of inertia of the tip axis is the allowable moment of inertia when the tip spline axis of the SCARA robot is converted to the center. The offset amount from the tip axis to the load center should be within the following values. If the position of the center of gravity of the load deviates from the tip axis, it is required to reduce the speed and acceleration as appropriate.

Horizontal directionVertical direction
Without gripper20mm or less50mm or less
With gripper0mm20mm or less

The vertical direction of the specifications with gripper is from the finger mounting surface of the gripper to the load center of gravity.

Guideline for acceleration / deceleration setting

If continuous operation is required, operate within the range of the graph for acceleration / deceleration setting and duty cycle setting guideline.

PTP operation

For speed and acceleration / deceleration, the operable value when the transport load is taken into consideration is set as 100% (optimal speed / optimum acceleration / deceleration feature). Adjust to the desired speed and acceleration / deceleration.

(1) Optimal speed / optimum acceleration / deceleration feature does not provide guarantee for it to operate in all operation patterns.

(2) Slow down the speed or acceleration / deceleration as appropriate if significant vibration occurs, for it may cause a malfunction or may shorten its service life.

CP operation

Set the speed and acceleration / deceleration up to the values in the graph below.

(1) Slow down the speed or acceleration / deceleration as appropriate if significant vibration occurs, for it may cause a malfunction or may shorten its service life.

Duty cycle setting

The duty cycle is the operating rate in percentage (%) of the time the robot is operating during one cycle. This robot has a duty cycle limit based on ambient temperature to suppress the heat generation of the motor unit and reducing gear. Operate both PTP and CP operation within the values in the graph below. Do not run a continuous operation for more than 30 minutes.

(1) Operate with duty cycle within the upper limit for this may shorten the service life of the motor unit and the reducing gear.

Oversea specification

Important notes on selection

(1) Refer to page 4-747 for (Note 1) to (Note 5).
(2) Vertical axis is standard installed with a brake.
(3) Vertical axis does not support push control.
(4) If a tool is installed or a spring or other buffer is provided for push-motion, the allowable push force is 45 N.
(5) The arm will once extend in a straight line when switching the arm thread. Please be careful of interference with peripheral devices.
(6) Flange option is available. Refer to page 4-742 for further details.

Return to the page top

Dimension drawing

(Note) The controller connecting cable will be 3 units instead when the 3-axis specification is selected.

(Note) The overhang limit for gripper installed specification is 0 mm horizontally and 20 mm vertically. (Refer to the page 4-747 (Note 5))

Mass

HeadingContents
Mass3-axis type7.5kg
4-axis type8.0kg
3-axis specification
with medium gripper (GM)
8.0kg