LSA-S10SM

Main specification

HeadingContents
HorizontalLoad capacityMaximum load capacity (kg)15
Speed/ Acceleration/DecelerationMaximum speed (mm/s)2500
Rated acceleration/deceleration (G)1
Maximum acceleration/deceleration (G)3
ThrustRated thrust (N)65
Max. thrust (N)260
StrokeMinimum stroke (mm)60
Maximum stroke (mm)1860
Stroke pitch (mm)90

HeadingContents
Drive systemLinear servo motor
Accuracy of Repeating Positioning.±0.005mm
Lost motion0.02mm and below
BaseBase: Aluminum, with white alumite treatment
Linear guideInfinite linear circulation type
Allowable static moment value
Allowable dynamic moment value
(Note1)
Ma:56N・m
Mb:80N・m
Mc:48N・m
Ambient operating temperature and humidity0 - 40℃, Max 85% RH and below (No condensation shall occur)
Protection gradeIP20
Vibration resistant/Shock resistant4.9m/s2 100Hz and below
Compatible to overseas standardsRoHS compliant
Motor typeAC servo motor
Encoder typeIncremental
Encoder pulse No.1μm 
DeliveryWritten in [Reference for delivery] section of the homepage

(Note1) Values shown are for basic rated life of 10,000km. Life time travelling distance differs based on operating condition and attached condition.

 Please refer to page 1-342 for life time travelling distance.

Slider type moment direction

Stroke and maximum speed

(Measured in mm/s)

Stroke
(mm)
60~1860
(90mm intervals)
Maximum speed
(mm/s)
2500

Correlation Diagram of Acceleration and Load Capacity

The diagram shows the acceleration achieved at each load capacity, based on operation at a speed of 2500mm/s. Please use this information to select a suitable model which fulfils the desired carrying condition (work mass).

(Note) Take note that duty is not considered in the diagram.

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork ※Select
DVCCCIEPRCNMLML3ECEPPRTSSNECM
SCON-CB/CGB1Single phase AC200V512
(768 for network specification)
SCON-LC/LCG1512
(768 for network specification)
SSEL-CS220000
XSEL-P/Q6Single phase AC200V
Three-phase AC200V
20000

(Note) Please refer page 7-15 for network abbreviations such as DV and CC.

(Note) No connection is available for 5th and 6th axis of XSEL-P/Q.

(Note) Either 2 units of SCON, or a 2-axis controller is required to operate a multi slider.

Oversea specification

Important notes on selection

(1) In some cases where the strokes are too short, it may not be able to reach its maximum speed.
(2) Load capacity shown in the "Main specification" refers to their maximum load capacity. Load capacity differs based on operating condition. Please refer to "Correlation Diagram of Acceleration and Load Capacity" for further information.
(3) Kindly take note that the device doesn’t support vertical mounting.
(4) Safety measures may be required depending on the attachment orientation. Please refer to page 1-361 for further details.
(5) In any instance to set the cableveyor position in mirroring position, fix the main body upon rotating by 180° in horizontal direction for the main body is built in bilateral symmetry.
(6) Standard value for offset load lengths are 300mm and below, towards the direction of Ma, Mb and Mc.

Return to the page top

Dimension drawing

Horizontal specification (Standard)

ST: Stroke

M.E.: Mechanical end

(Note) While returning to home position, please ensure that there will be no interfering object for the slider moves to M.E. during the process.

(Note) No additional cables can be fixed into the standard cableveyor. Kindly use the cableveyor for user to fix additional cable.

Dimension by stroke length

Stroke601502403304205106006907808709601050114012301320141015001590168017701860
L6107007908809701060115012401330142015101600169017801870196020502140223023202410
B5646547448349241014110411941284137414641554164417341824191420042094218422742364
C224141041942847416425444134224141041942847416425444134224
D122223334445555666777
E81212121216161620202024242424282828323232
J3244145045946847748649541044113412241314140414941584167417641854194420342124

Mass by stroke length

Stroke601502403304205106006907808709601050114012301320141015001590168017701860
Mass (kg)13.514.415.216.016.917.718.619.420.221.121.922.723.624.425.226.126.927.728.629.430.2

Laterally laid specification (Standard)

ST: Stroke

M.E.: Mechanical end

(Note) While returning to home position, please ensure that there will be no interfering object for the slider moves to M.E. during the process.

(Note) No additional cables can be fixed into the standard cableveyor. Kindly use the cableveyor for user to fix additional cable.

Dimension by stroke length

Stroke601502403304205106006907808709601050114012301320141015001590168017701860
L6107007908809701060115012401330142015101600169017801870196020502140223023202410
B5646547448349241014110411941284137414641554164417341824191420042094218422742364
C224141041942847416425444134224141041942847416425444134224
D122223334445555666777
E81212121216161620202024242424282828323232
J3244145045946847748649541044113412241314140414941584167417641854194420342124

Mass by stroke length

Stroke601502403304205106006907808709601050114012301320141015001590168017701860
Mass (kg)14.515.416.217.017.918.719.620.421.222.122.923.724.625.426.227.127.928.729.630.431.2