LSA-S6SS

Main specification

HeadingContents
HorizontalLoad capacityMaximum load capacity (kg)3
Speed/ Acceleration/DecelerationMaximum speed (mm/s)2500
Rated acceleration/deceleration (G)1
Maximum acceleration/deceleration (G)3
ThrustRated thrust (N)15
Max. thrust (N)60
StrokeMinimum stroke (mm)48
Maximum stroke (mm)1248
Stroke pitch (mm)48

HeadingContents
Drive systemLinear servo motor
Accuracy of Repeating Positioning.±0.005mm
Lost motion0.02mm and below
BaseBase: Aluminum, with white alumite treatment
Linear guideInfinite linear circulation type
Allowable static moment value
Allowable dynamic moment value
(Note1)
Ma:50N・m
Mb:71N・m
Mc:17N・m
Ambient operating temperature and humidity0 - 40℃, Max 85% RH and below (No condensation shall occur)
Protection gradeIP20
Vibration resistant/Shock resistant4.9m/s2 100Hz and below
Compatible to overseas standardsRoHS compliant
Motor typeAC servo motor
Encoder typeIncremental
Encoder pulse No.1μm 
DeliveryWritten in [Reference for delivery] section of the homepage

(Note1) Values shown are for basic rated life of 10,000km. Life time travelling distance differs based on operating condition and attached condition.

 Please refer to page 1-342 for life time travelling distance.

Slider type moment direction

Stroke and maximum speed

(Measured in mm/s)

Stroke
(mm)
48~1248
(48mm intervals)
Maximum speed
(mm/s)
2500

Correlation Diagram of Acceleration and Load Capacity

The diagram shows the acceleration achieved at each load capacity, based on operation at a speed of 2500mm/s. Please use this information to select a suitable model which fulfils the desired carrying condition (work mass).

(Note) Take note that duty is not considered in the diagram.

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork ※Select
DVCCCIEPRCNMLML3ECEPPRTSSNECM
SCON-CB/CGB1Single phase AC200V512
(768 for network specification)
SCON-LC/LCG1512
(768 for network specification)
SSEL-CS2Single phase AC
100V/200V
20000
XSEL-P/Q6Single phase AC200V
Three-phase AC200V
20000

(Note) Please refer page 7-15 for network abbreviations such as DV and CC.

(Note) No connection is available for 5th and 6th axis of XSEL-P/Q.

Oversea specification

Important notes on selection

(1) In some cases where the strokes are too short, it may not be able to reach its maximum speed.
(2) Load capacity shown in the "Main specification" refers to their maximum load capacity. Load capacity differs based on operating condition. Please refer to "Correlation Diagram of Acceleration and Load Capacity" for further information.
(3) Kindly take note that the device doesn’t support vertical mounting.
(4) Safety measures may be required depending on the attachment orientation. Please refer to page 1-361 for further details.
(5) Standard value for offset load lengths are 300mm and below, towards the direction of Ma, Mb and Mc.

Return to the page top

Dimension drawing

Horizontal specification (Standard)

ST: Stroke

M.E.: Mechanical end

S.E.: Stroke end

(Note) While returning to home position, please ensure that there will be no interfering object for the slider moves to M.E. during the process.

(Note) No additional cables can be fixed into the standard cableveyor. Kindly use the cableveyor for user to fix additional cable.

Dimension by stroke length

Stroke4896144192240288336384432480528576624672720768816864912960100810561104115212001248
L334382430478526574622670718766814862910958100610541102115011981246129413421390143814861534
B29834639444249053858663468273077882687492297010181066111411621210125813061354140214501498
C287612417220681161641260108156204521001481964492140188368413218028
D11112222333334444555566667
E888812121212161616161620202020242424242828282832
J1281762242723203684164645125606086567047528008488969449921040108811361184123212801328
R148173198223248273298323348373398423448473498523548573598623648673698723748773

Mass by stroke length

Stroke4896144192240288336384432480528576624672720768816864912960100810561104115212001248
Mass (kg)3.13.33.53.73.94.14.34.54.75.05.25.45.65.86.06.26.46.66.87.07.37.57.77.98.18.3

Laterally laid specification (Standard)

ST: Stroke

M.E.: Mechanical end

S.E.: Stroke end

(Note) While returning to home position, please ensure that there will be no interfering object for the slider moves to M.E. during the process.

(Note) No additional cables can be fixed into the standard cableveyor. Kindly use the cableveyor for user to fix additional cable.

(Note) Mirrored specification, CT6 moves in reverse direction while returning to home position.

(Note) To use UM5, an option of cableveyor for user, please provide space by removing all interfering objects away from cableveyor sides. You may use US5 (s type) instead if there were no space to be provided.

Dimension by stroke length

Stroke4896144192240288336384432480528576624672720768816864912960100810561104115212001248
L334382430478526574622670718766814862910958100610541102115011981246129413421390143814861534
B29834639444249053858663468273077882687492297010181066111411621210125813061354140214501498
C287612417220681161641260108156204521001481964492140188368413218028
D11112222333334444555566667
E888812121212161616161620202020242424242828282832
J1281762242723203684164645125606086567047528008488969449921040108811361184123212801328

Mass by stroke length

Stroke4896144192240288336384432480528576624672720768816864912960100810561104115212001248
Mass (kg)3.63.84.04.24.44.64.85.05.25.55.75.96.16.36.56.76.97.17.37.57.88.08.28.48.68.8