RCA2-SA4C

Actuator specification

ModelMotor output
(W)
Lead
(mm)
Maximum Load CapacityRated thrust
(N)
Stroke
(mm)
Horizontal (kg)Vertical (kg)
RCA2-SA4C-I-20-10-①-②-③-④2010213450 - 500
(50mm intervals)
RCA2-SA4C-I-20-5-①-②-③-④541.568
RCA2-SA4C-I-20-5-①-②-③-④2.563136

Symbol description ① Stroke ② Adaptive controller ③ Cable length ④ Option

Stroke
lead
50 - 500
(50mm intervals)
10500
5250
2.5125

(Measured in mm/s)

Actuator specification

HeadingContents
Drive systemBall screw φ8mm, rolled C10
Accuracy of Repeating Positioning.±0.02mm
Lost motion0.1mm and below
BaseBase: Aluminum, with exclusive alumite treatment
Allowable static moment valueMa:6.8N・m Mb:9.7N・m Mc:13.3N・m
Allowable dynamic moment (Note1)Ma:3.49N・m Mb:4.98N・m Mc:6.78N・m
Ambient operating temperature and humidity0 - 40℃, 85% RH Max (Non-condensation)

(Note1) Values shown are for basic rated life of 5,000km. Life time travelling distance differs based on operating condition and attached condition.

 Please refer to page 1-360 for life time travelling distance.

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork ※Select
DVCCCIEPRCNMLML3ECEPPRTSSNECM
ACON-CB/CGB1DC24V
※Selectable

※Selectable
512
(768 for network specification)
ACON-CYB/PLB/POB1
※Selectable

※Selectable
64
ASEL-CS21500
MCON-C/CG8256
MCON-LC/LCG6256
RCON16128

(Note) Please refer to page 6 -13 for abbreviated names of network (e.g. DV, CC).

Oversea specification

Feature

Important notes on selection

(1) Load capacity shown assumes an operation in 0.3G (0.2G for lead 2.5 and vertical oriented), which is the upper limit of acceleration.
(2) Availability of duty depends on the operating condition (e.g.load mass, acceleration/deceleration). Please refer to page 1-448 for further details.
(3) Encoder type box for model item will be "I" for simple absolute as well.
(4) The standard value for offset load lengths are 120mm and below, towards the direction of Ma, Mb and Mc. Please refer to the diagram on page 1-104 for offset load length.
(5) Safety measures may be required depending on the attachment orientation. Please refer to page 1-379 for further information.

Return to the page top

Dimension drawing

ST: Stroke

ME: Mechanical end

SE: Stroke end

※1 Connect a motor/encoder cable (integrated model). Please refer to page 1-293 for the further details about the cable.

※2 Ensure the slider does not collide with other items, for it will return to ME after homing process.

Dimension/Mass by stroke

Stroke50100150200250300350400450500
LBrake present274324374424474524574624674724
Brake absent314.5364.5414.5464.5514.5564.5614.5664.5714.5764.5
A165.5215.5265.5315.5365.5415.5465.5515.5565.5615.5
B91419141914191419141
C0112233445
D466881010121214
M91141191241291341391441491541
Mass (kg)With cover0.911.11.11.21.31.41.51.51.6
Without cover0.80.9111.11.21.31.31.41.5

(Note) There will be an additional mass of 0.3kg for specification with brake.