Actuator specification

ModelLead
(mm)
Max. Load capacity (Note1)Maximum pressing force
(N)
Stroke
(mm)
Horizontal (kg)Vertical (kg)
RCP2-RA3C-I-28P-5-①-②-③-④515673.550 - 200
(50mm intervals)
RCP2-RA3C-I-28P-2.5-①-②-③-④2.53010156.8

Symbol description ① Stroke ② Adaptive controller ③ Cable length ④ Option

(Note1) Please be aware that maximum load capacity drops when operated in high speed.

Stroke
lead
50 - 200
(50mm intervals)
5187
2.5114

(Measured in mm/s)

Correlation diagram of speed and load capacity

RCP2 series follows the characteristic of the pulse motor installed in them, where the load capacity drops when operated in high speed. Search for desired speed and load capacity from the table below.

Actuator specification

HeadingContents
Drive systemBall screw φ8mm, rolled C10
Accuracy of Repeating Positioning.±0.02mm
Lost motion0.1mm and below
Rod diameterφ22mm
Non-rotational accuracy of rod±1.5°
Ambient operating temperature and humidity0 - 40℃, RH 85% and below (no condensation)

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork ※Select
DVCCCIEPRCNMLML3ECEPPRTSSNECM
MCON-C/CG8DC24V256
MCON-LC/LCG6256
MSEL-PC/PG4Single phase
AC 100 - 230V
30000
PCON-CB/CGB1DC24V
※Selectable

※Selectable
512
(768 for network specification)
PCON-CYB/PLB/POB1
※Selectable

※Selectable
64
RCON16128
PSEL-CS21500

(Note) Please refer to page 6 -13 for abbreviated names of network (e.g. DV, CC).

Oversea specification

Important notes on selection

(1) RCP2 series follows the characteristic of the pulse motor installed in them, where the load capacity drops when operated in high speed. Check the "Correlation diagram of speed and load capacity" for load capacity of the desired speed.
(2) Load capacity assuming an acceleration of 0.2G, which is its upper limit for acceleration. Horizontal load capacity shown assumes an operation running with an external guide. Detent mechanism may get damaged if a force was applied to the rod, except towards its moving direction.
(3) Please refer to page 1-387 of general catalogue 2017 for further details of pressing motion.
(4) Encoder type box for model item will be "I" for simple absolute as well.
(5) Safety measures may be required depending on the attachment orientation. Please refer to page 1-379 for further information.
(6) Conversion unit or cable is needed to connect RCON. Please refer to page Home for further details.

Return to the page top

Dimension drawing

ST: Stroke

ME: Mechanical end

SE: Stroke end

※1 Connect a motor/encoder cable. Please refer to page 1-291 for the further details about the cable.

*2 The rod moves to the ME upon returning to origin, so please take precaution that it may not interfere with anything while the returning process is running.

*3 The direction the width between two flats are facing differs by product.

(Note) Do not apply any external force on to the rod except towards the direction of its movement. Detent mechanism may get damaged if a force was applied to the rod from its right angle, or towards its rotating direction.

Dimension/Mass by stroke

Stroke50100150200
112.5162.5212.5262.5
L203253303353
N1234
n681012