Main specification

HeadingContents
LeadBall screw lead (mm)1684
HorizontalLoad capacity (Note 2)Maximum load capacity (kg)506585
Speed/ Acceleration/DecelerationMaximum speed (mm/s)420280130
Minimum speed (mm/s)20105
Rated acceleration/deceleration (G)0.30.30.1
Maximum acceleration/deceleration (G)111
VerticalLoad capacityMaximum load capacity (kg)11.521.5
Speed/ Acceleration/DecelerationMaximum speed (mm/s)210130
Minimum speed (mm/s)105
Rated acceleration/deceleration (G)0.50.1
Maximum acceleration/deceleration (G)0.50.5
Pressing motionMax. pressing thrust (N)2735471094
Max. pressing speed (mm/s)202020
BrakeBrake specificationNon-excitation electromagnetic brake
Brake retention force (kgf)11.521.5
StrokeMinimum stroke (mm)505050
Maximum stroke (mm)600600600
Stroke pitch (mm)505050

(Note 2) Assuming radial load supported by an external guide.

HeadingContents
Drive systemBall screw φ12mm, rolled C10
Accuracy of Repeating Positioning.±0.01mm
Lost motion0.1mm or less
Rod guideInfinite linear circulation type
Main materialRodφ40mm stainless steel with hard chrome plating
FrameWhite alumite treated aluminum
Dust sealRubber (NBR)
Actuator cablePolyvinyl chloride (PVC)
Rod non-rotation accuracy (Note 3)0 degrees
Ambient operating temperature and humidity0 - 40℃, RH 85% and below (no condensation)
Protection gradeIP65(IEC60529/JIS0920)
Vibration resistant/Shock resistant4.9m/s2
Compatible to overseas standardsCE mark, RoHS compliant
Motor typePulse motor
Encoder typeBattery-less absolute
Encoder pulse No.8192 pulse/rev
DeliveryWritten in [Reference for delivery] section of the homepage

(Note 3) This is the displacement angle in the rod rotation direction when there is no load.

Stroke and maximum speed

If the environmental temperature exceeds 5℃

(Measured in mm/s)

Lead
(mm)
50 - 600
(Every 50mm)
16420
8280<210>
4130

(Note) < > is applicable when operated vertically.

If the environmental temperature is 5℃ or less

(Measured in mm/s)

Lead
(mm)
50 - 600
(Every 50mm)
16280
8140
470

Correlation diagram of pressing force and current limiting value

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork *Select
DVCCCIEPRCNMLML3ECEPPRTSSNECM
MSEL-PC/PG4Single phase AC
100 - 230V
30000
PCON-CB/CGB1DC24V
*Selectable

*Selectable
512
(768 for network specification)
PCON-CYB/PLB/POB1
*Selectable

*Selectable
64
RCON16
(ML3,SSN,ECM is 8)
128
(Position data unavailable for ML3, SSN and ECM)
RSEL836000

(Note) Refer to page 8-17 for network abbreviations such as DV and CC.

(Note) See page 8-139 for built-in controllers for RCP6S series.

Oversea specification

Important notes on selection

(1) The payload indicated in the "Main Specification" is the maximum value. Please refer to "Load capacity by speed and acceleration table" for further information.
(2) Radial cylinder has a built-in guide. Please refer to "Allowable load at the tip of the rod" for the allowable load mass. Refer to page 1-299 for further details.
(3) Please refer to "Correlation diagram of pressing force and power supply limit value" if you may need it to perform pressing operation. Pressing force shown are their standard value. Refer page 1-269 for notes to be considered.
(4) For lead 4/8/16 of RCP6SW (built-in controller), the duty has to be limited depending on the ambient temperature. Refer to page 1-280 for further details.
(5) The cable joint connector is not drip-proof. Please install it in a place where it will not be exposed to water.
(6) The RCP6SW with built-in controller does not have a port for connecting the teaching tool. Connect the teaching tool to the gateway unit to set the parameter data, etc..
(7) Safety measures may be required depending on the attachment orientation. Refer to page 1-261 for further details.

Return to the page top

Dimension drawing

RCP6W-WRA14R

ST: Stroke

M.E.: Mechanical end

S.E.: Stroke end

*1 Select the total length of the actuator cable and actuator/controller connection cable so that the total length is 20m or less.

*2 The cable relay part (cable joint connector) inside the broken line is not drip-proof.

(Note) The rod moves to the M.E. upon returning to origin, so please take precaution that it may not interfere with anything while the returning process is running.

(Note) If the overhang of the transported object is large or if strict angle adjustment is required, install the transported object without using the reamer hole.

(Note) Please refer to pages 1-344 for the material of each part.

(Note) Diagram below shows the motor left-reversing specification (ML).

Dimension by stroke length

Stroke50100150200250300350400450500550600
L303.4353.4403.4453.4503.4553.4603.4653.4703.4753.4803.4853.4
A277.4327.4377.4427.4477.4527.4577.4627.4677.4727.4777.4827.4
B198248298348398448498548598648698748
F108581085810858108581085810858
G011112233445
H4668810101212141416
J158208258308358408458508558608
M111222222222
Allowable static load at the rod tip (N)454392345307276251229210193179166154
Allowable static torque at the rod tip (Nm)303030303030303030303030
3000kmAllowable dynamic load on the rod tip(N)Off-set 0mm199170148131117104948577706458
Off-set 150mm10010010010010095877972666055
Allowable dynamic torque at the rod tip (N・m)15.015.015.015.015.014.313.011.810.89.99.08.2
5000kmAllowable dynamic load on the rod tip(N)Off-set 0mm1671431241099787787063575146
Off-set 150mm100100100968779716559534844
Allowable dynamic torque at the rod tip (N・m)15.015.015.014.413.011.810.79.78.88.07.36.6

Mass by stroke length

Stroke50100150200250300350400450500550600
Mass
(kg)
RCP6WWithout brake9.410.211.112.012.913.814.715.616.517.418.319.2
With brake9.510.311.212.113.013.914.815.716.617.518.419.3
RCP6SWWithout brake9.610.411.312.213.114.014.915.816.717.618.519.4
With brake9.710.511.412.313.214.115.015.916.817.718.619.5

RCP6SW-WRA14R

ST: Stroke

M.E.: Mechanical end

S.E.: Stroke end

*1 Select the total length of the actuator cable and power supply or I/O cable so that the total length is 20m or less.

*2 The cable relay part (cable joint connector) inside the broken line is not drip-proof.

(Note) The rod moves to the M.E. upon returning to origin, so please take precaution that it may not interfere with anything while the returning process is running.

(Note) If the overhang of the transported object is large or if strict angle adjustment is required, install the transported object without using the reamer hole.

(Note) Please refer to pages 1-344 for the material of each part.

(Note) Diagram below shows the motor left-reversing specification (ML).

(Note) Please refer to the previous page for the dimensions and mass of RCP6SW by stroke.

Flexible volume (reference value)

Allowable load at the tip of the rod

Horizontal

Condition required upon calculating allowable load mass

A load mass with a guide running life of 5000 km, taking into account the moment of acceleration and deceleration.

(Acceleration of 1G, and speed of 500mm/s)

Vertical

Condition required upon calculating allowable load mass

A load mass with a guide running life of 5000 km, taking into account the moment of acceleration and deceleration.

(Acceleration of 0.5G, and speed of 210mm/s)

Feature

Loadable mass table by speed/acceleration * Refer to page 1-25 for details on high output settings.

High output setting enabled If the environmental temperature exceeds 5℃ Maximum speed varies depending on the transport mass. The base unit for load capacity is kilogram (kg). Empty column refers to inoperable motion.

Lead 16

OrientationHorizontal
SpeedAcceleration (G)
(mm/s)0.10.30.50.71
05050403530
1405050403530
2805032251712
4202372

Lead 8

OrientationHorizontalVertical
SpeedAcceleration (G)
(mm/s)0.10.30.50.710.10.30.5
0656555504511.511.511.5
70656555504511.511.511.5
14065655141419.59.56.5
21065562820151.51.5
28051141

Lead 4

OrientationHorizontalVertical
SpeedAcceleration (G)
(mm/s)0.10.30.50.710.10.30.5
0858070656021.519.519.5
35858070656021.519.519.5
70858070656021.519.519.5
105858051464015.513.512
130854110623.5

Portable mass table by speed/acceleration (high output setting enabled (5℃ or less))

High output setting enabled If the environmental temperature is 5℃ or less Maximum speed varies depending on the transport mass. The base unit for load capacity is kilogram (kg).

Lead 16

OrientationHorizontal
SpeedAcceleration (G)
(mm/s)0.10.30.50.71
05050403530
1405050403530
2805032251712

Lead 8

OrientationHorizontalVertical
SpeedAcceleration (G)
(mm/s)0.10.30.50.710.10.30.5
0656555504511.511.511.5
70656555504511.511.511.5
14065655141419.59.56.5

Lead 4

OrientationHorizontalVertical
SpeedAcceleration (G)
(mm/s)0.10.30.50.710.10.30.5
0858070656021.519.519.5
35858070656021.519.519.5
70858070656021.519.519.5