RCS2-SA5D

Actuator specification

ModelMotor output
(W)
Lead
(mm)
Maximum Load CapacityRated thrust
(N)
Stroke
(mm)
Horizontal (kg)Vertical (kg)
RCS2-SA5D-①-20-12-②-T2-③-④20124116.750 - 500
(50mm intervals)
RCS2-SA5D-①-20-6-②-T2-③-④68233.3
RCS2-SA5D-①-20-3-②-T2-③-④312465.7

Symbol description ① Encoder type ② Stroke ③ Cable length ④ Option

Stroke
lead
50 - 450
(50mm intervals)
500
(mm)
12800760
6400380
3200190

(Measured in mm/s)

Actuator specification

HeadingContents
Drive systemBall screw φ10mm, rolled C10
Accuracy of Repeating Positioning.±0.02mm
Lost motion0.1mm and below
BaseBase Aluminum, with white alumite treatment
Allowable static moment valueMa:18.6N・m Mb:26.6N・m Mc:47.5N・m
Allowable dynamic moment (Note1)Ma:5.81N・m Mb:8.30N・m Mc:14.8N・m
Ambient operating temperature and humidity0 - 40℃, 85% RH Max (Non-condensation)

(Note1) Values shown are for basic rated life of 5,000km. Life time travelling distance differs based on operating condition and attached condition.

 Please refer to page 1-360 for life time travelling distance.

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork ※Select
DVCCPRCNMLML3ECEPPRTSSNECM
MSCON-C6Single phase AC
100V/200V
256
SCON-CAL/CGAL1512
(768 for network specification)
SCON-CB/CGB1512
(768 for network specification)
SCON-LC/LCG1512
(768 for network specification)
SSEL-CS220000
XSEL-P/Q6Single phase AC200V
Three-phase AC200V
20000
XSEL-RA/SA855000
(Vary based on type)

(Note) Please refer to page 6 -13 for abbreviated names of network (e.g. DV, CC).

Oversea specification

(Note) CE is optional.

Important notes on selection

(1) When the stroke increases, the maximum speed will drop to prevent the ball screw from reaching the critical rotational speed. Use the "Stroke and Max.speed" to check the maximum speed at the stroke you desire.
(2) Load capacity shown assumes an operation in 0.3G (0.2G for lead 3), which is the upper limit of acceleration.
(3) Available duty depends on the operating condition (e.g.load mass, acceleration/deceleration). Please refer to page 1-448 for further details.
(4) The standard value for offset load lengths are 150mm and below, towards the direction of Ma, Mb and Mc. Please refer to the diagram on page 1-104 for offset load length.
(5) Safety measures may be required depending on the attachment orientation. Please refer to page 1-379 for further information.

Return to the page top

Dimension drawing

ME: Mechanical end

SE: Stroke end

※1 Connect a motor/encoder cable. Please refer to page 1- 295 for the further details about the cable.

※2 Ensure the slider does not collide with other items, for it will return to ME after homing process.

(Note) There will be an additional length (L) of 26.5mm (39.8mm if wiring exits from the end) and additional mass of 0.3kg.

Dimension/Mass by stroke

Stroke50100150200250300350400450500
L263.5313.5363.5413.5463.5513.5563.5613.5663.5713.5
A172222272322372422472522572622
M142192242292342392442492542592
N50100100200200300300400400500
P358585185185285285385385485
R42429242924292429242
U112233445
m4446688101012
Mass (kg)1.41.51.61.71.81.92.02.12.22.3