RCS2W-GS5NB

Main specification

HeadingContents
LeadBall screw lead (mm)1052.5
HorizontalLoad capacityMaximum load capacity (kg)51020
Speed/ Acceleration/DecelerationMaximum speed (mm/s)380250125
Rated acceleration/deceleration (G)0.30.30.2
Maximum acceleration/deceleration (G)0.30.30.2
VerticalLoad capacityMaximum load capacity (kg)1.536
Speed/ Acceleration/DecelerationMaximum speed (mm/s)330250125
Rated acceleration/deceleration (G)0.20.20.2
Maximum acceleration/deceleration (G)0.20.20.2
ThrustRated thrust (N)89178356
StrokeMinimum stroke (mm)505050
Maximum stroke (mm)757575
Stroke pitch (mm)252525

HeadingContents
Drive systemBall screw φ8mm, rolled C10
Accuracy of Repeating Positioning.±0.02mm
Lost motion0.1mm or less
Main materialRodSUS440C
FrameWhite alumite treated aluminum
Rubber CoverChloroprene Rubber (CR)
Actuator cablePolyvinyl chloride (PVC)
Rod non-rotation accuracy
Life time traveling distance5000km, or 50 million round trips
Air purgeNot allowed
Ambient operating temperature and humidity0 - 40℃, RH 85% and below (no condensation)
Protection gradeIP52
Vibration resistant/Shock resistant4.9m/s2
Compatible to overseas standardsCE mark, RoHS compliant
Motor typeAC servo motor
Encoder typeIncremental
Encoder pulse No.1600pulse/rev
DeliveryWritten in [Reference for delivery] section of the homepage

Stroke and maximum speed

(Measured in mm/s)

Stroke
lead
50
(mm)
75
(mm)
10280<230>380<330>
5250<230>250
2.5125

(Note) < > is applicable when operated vertically.

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork *Select
DVCCCIEPRCNMLML3ECEPPRTSSNECM
RCON16
(ML3,SSN,ECM is 8)
DC24V,
single phase AC200V,
three phase AC200V
128
(Position data unavailable for ML3, SSN and ECM)
RSEL836000
SCON-CB/CGB1Single phase AC
100V/200V
512
(768 for network specification)
SSEL-CS220000
XSEL-P/Q6Single phase AC200V
Three-phase AC200V
20000

(Note) Refer to page 8-17 for network abbreviations such as DV and CC.

(Note) 5th and 6th XSEL-P/Q can't be connected.

Oversea specification

(Note) CE is optional.

Important notes on selection

(1) The horizontal payload indicated is the value assuming a there was a guide to prevent radial load and a moment load from being applied to the rod. To run it without a guide, please refer to the relationship between the allowable load at the tip and the running life (→ page 1-293). Single guide can't be used here if there is a force applied towards the rotating direction. Double guide shall be used instead.
(2) Load capacity assuming an horizontal acceleration of 0.3G (0.2G for lead 2.5) and vertical acceleration of 0.2G, which is their upper limit for acceleration.
(3) The guideline for usable duty varies depending on the operating conditions (transport mass, acceleration/deceleration, etc.). Refer to page 1-282 for further details.
(4) When using vertically, be careful of interference as the rod descends when the power turns off.
(5) Safety measures may be required depending on the attachment orientation. Refer to page 1-261 for further details.

Return to the page top

Dimension drawing

ST: Stroke

M.E.: Mechanical end

S.E.: Stroke end

(Note) The rod moves to M.E. at homing. Please be careful of interference with surrounding objects.

(Note) The connector at the end of the actuator cable is not subject to the protective structure.

(Note) The screwing depth should be equal or less than the indicated dimensions.

Dimension by stroke length

Stroke5075
L113138
D40.546.5

Mass by stroke length

Stroke5075
Mass (kg)Without brake1.381.48