Model specification
Model | Axis Configuration | Encoder type | Motor type | Lead (mm) | Stroke (mm) | Speed (mm/s) | Load Capacity (kg) |
---|---|---|---|---|---|---|---|
TTA-C2SL(G)-WA-20①-15②-③-④-⑤-⑥-⑦-⑧ | X axis | Battery-less absolute | AC servo motor | 8 | 200 | 1 - 600 | - |
Y axis | 8 | 150 | 1 - 600 | 20 | |||
TTA-C2SH(G)-WA-20①-15②-③-④-⑤-⑥-⑦-⑧ | X axis | Equivalent to 13.3 | 200 | 1 - 700 | - | ||
Y axis | Equivalent to 13.3 | 150 | 1 - 600 | 12 | |||
TTA-C2(G)-WA-20①-15②-③-④-⑤-⑥-⑦-⑧ | X axis | Pulse motor | Equivalent to 24 | 200 | 1 - 600 | - | |
Y axis | Equivalent to 24 | 150 | 1 - 540 | 10 |
Description of symbols ① ② XY-axis option ③ Standard I/O slot ④ ⑤ Expansion I/O slot ⑥ I/O cable length ⑦ Electric cable specification ⑧ Option
Actuator specification
Heading | Contents | |
---|---|---|
AC servo motor | Pulse motor | |
Drive system | Ball screw (φ12mm Rolled, C5 equivalent) High lead: Speed reduces by 1:1.2 using a timing belt | Ball screw (φ12mm Rolled, C10) Speeds up by 1.5:1 using a timing belt |
Accuracy of Repeating Positioning. | ±0.005mm | ±0.01mm |
Lost motion | Low lead: 0.025 mm or less High lead: 0.04 mm or less | 0.05mm and below |
Dynamic allowable moment | X-axis:Ma:14.9N・m Mb:14.9N・m Mc:44.3N・m Y-axis:Ma:14.9N・m Mb:14.9N・m Mc:44.3N・m | |
Ambient temperature/humidity | 0 - 40℃, RH 85% and below (no condensation) | |
Table part loading weight | 40kg | |
Body weight | 25kg |
Oversea specification
(Note) CE is compatible only with safety category compliant specifications.
Important notes on selection
(1) The maximum acceleration/deceleration differs depending on the load capacity. (Refer to page 4-667) The maximum speed cannot be achieved with the pulse motor at the maximum payload setting. If increase speed, the load capacity will drop. (Refer to page 4-669) (2) Positioning repeatability is applicable only when the main body temperature is constant. It will not guarantee the absolute accuracy. (3) The value of the dynamic allowable moment is the value of each axis. When the standard rated life is 5,000 km and the standard load factor is 1.5. (Refer to page 4-671 for the dynamic allowable moment.) (4) Enter "E" in the expansion I/O slot 1 and 2 of the model item if it is not used. |
Dimension drawing
ME: Mechanical end
SE: Stroke end
(Note) When fixing the work, make sure there is a margin of 2 mm or more for the moving range of the column.
(Note) During home return, the slider moves to the mechanical end. Pay attention to prevent contact between the slider and the surrounding.