IX-NNC50□□H

Main specification

HeadingContents
4-axis type
Maximum load capacity (kg)10
Speed
(Note 2)
Maximum resultant speed (mm/s)6381
Maximum speed of each axis1st arm (degree/s)487
2nd arm (degree/s)487
Vertical axis (mm/s)1473
Rotating axis (degree/s)1857
Push force (N) (Note 3)Upper limit180
Minimum93
Cleanroom CompatibleSuction amount (Nl/min)(Note 4)60
Arm length (mm)500
Arm length of each axis (mm)1st arm250
2nd arm250
Operating range of each axis1st arm (degree)±120
2nd arm (degree)±145
Vertical axis (mm)200【300】
Rotating axis (degree)±360

HeadingContents
4-axis type
Repeated positioning accuracy
(Note 5)
Horizontal plane±0.010 mm
Vertical axis±0.010 mm
Rotating shaft±0.005 degree
User wiring25-Core AWG26 (rated 30V/MAX1.1A) with shield
User pipingOuter diameter φ6 Inner diameter φ4 2 Air tubes (Max.working pressure 0.8MPa)
Outer diameter φ4 Inner diameter φ2.5 2 Air tubes (Max. working pressure 0.8MPa)
Alarm indicator light (Note 6)1 small red LED indicator (24V DC supply required)
Brake release switch (Note 7)Brake release switch for vertical axis fall prevention
Tip shaftAllowable torque3.7 N・m
Allowable load moment4.9 N・m
CleanlinessClass 10 (0.1 μm, Fed.Std.209D)
Class 2.5 equivalent (ISO 14644-1 standard)
Ambient operating temperature and humidityTemperature 0-40℃ Humidity 20-85% RH or less (no condensation)
Protection gradeIP30
Vibration resistant/Shock resistantNo shock or vibration
Noise (Note 8)73dB
Compatible to overseas standardsCE mark (optional), RoHS directive
Motor typeAC servo motor
Motor capacity1st arm400W
2nd arm200W
Vertical axis200W
Rotating shaft100W
Encoder typeAbsolute
Encoder pulse No.32768 pulse/rev
DeliveryWritten in [Reference for delivery] section of the homepage

Adaptive controller

The actuators introduced in this page are controllable using the controllers shown below. Please select their type based on intended usage.

NameAppearanceMax. connectable
axis No.
Power source voltageControl methodMaximum positioning points
PositionerPulse trainProgramNetwork *Select
DVCCCIEPRCNMLML3ECEPPRTSSNECM
XSEL-PX/QX6Three-phase AC200V20000
XSEL-RAX/SAX
XSEL-RAXD/SAXD (for IX)
836666
(depending on type)

(Note) Refer to page 8-17 for network abbreviations such as DV and CC.

(Note) It can control up to SCARA + 4-axis robot.

(Note) Select XSEL-RAXD / SAXD when connecting two SCARA robots. However, the SCARA robots may not be able to be connected depending on the combination. See page 8-291 for the further details.

Oversea specification

(Note) CE is optional.

Important notes on selection

(1) For (Note 1) to (Note 10), refer to page 7-393.
(2) SCARA robots cannot operate continuously at 100% speed and acceleration. See "Guidelines for acceleration/deceleration setting" for the operable conditions.
(3) The numbers noted in [ ] are for models with a vertical axis of 300 mm. Other specifications and dimensions are common for both vertical axis of 200 mm and 300 mm.
(4) An adjustment jig is required to perform absolute reset which is needed whenever the encoder absolute data was lost. Refer to page 7-402 for further details.
(5) Flange option is available. Refer to page 7-402 for further details.

Return to the page top

Dimension drawing

ST: Stroke

*1 The external force applied to the spacer should be 30N or less in the axial direction and 2N·m or less in the rotating direction. (For each spacer)

*2 The LED operates under a condition where the LED terminal is wired in the user's wiring so that it receives 24V of DC while receiving signals from the I/O output of the controller.

*3 3-M4 depth 8 penetrates the side of the arm. Please note that long mounting screws will interfere with internal mechanical components.

 Please be sure to use sealing tape etc. to seal the screws.

(Note) Cable/Piping

 ・Motor ・Encoder cable 5m/10m

 ・Brake power supply cable 5m/10m

 ・User wiring cable 5m/10m

 ・User piping (4 pipes) 0.15m

Mass

HeadingContents
Mass31.5kg

Guideline for acceleration / deceleration setting

SCARA Robot IX cannot operate continuously at the maximum acceleration/deceleration and maximum speed in the catalog. When operating at the maximum acceleration / deceleration, set the stop time by referring to the guideline graph of continuous operation duty. If continuous operation is required, operate with the acceleration / deceleration setting within the continuous operation guideline range described in guideline graph for acceleration / deceleration setting.

(1) In case of PTP operation, be sure to use the WGHT instruction on the program to set the mass and moment of inertia before operating. For SCARA high speed compatible products,the maximum acceleration / deceleration that can operate at each transport mass is set as 100%. Please note that the operating time will be different if the transport mass is different even if the acceleration / deceleration and speed settings are the same.

(2) Adjust the acceleration / deceleration by gradually increasing the set value from the continuous operation guideline value.

(3) If an overload error occurs, reduce the acceleration/deceleration as appropriate, or make adjustments to set a stop time by referring to the guideline for continuous operation duty.

(4) Duty (%) = (Operating time / (Operating time + Stopping time)) x 100

(5) If you wish to move the robot horizontally at high speed, move the vertical axis as close to the rising end as possible.

(6) Keep the moment of inertia and the loaded mass below the allowable values.

(7) The transport load indicates the moment of inertia and mass of the center of rotation of the 4th axis.

(8) Operate the robot with an appropriate acceleration / deceleration based on the mass and moment of inertia. Failure to do so will result in shortened life span, damage and vibration of the drive.

(9) If the moment of inertia of the load is large, vibration may occur at the vertical axis depending on its position. If vibration occurs, slow down the acceleration / deceleration as appropriate.

PTP operation

CP operation

Cycle time

HeadingTime
Standard Cycle Time0.41 sec

The standard cycle time indicates the required time when operating with the fastest round-trip operation setting under the following conditions.

Transfer mass of 2kg, vertical movement of 25mm and horizontal movement of 300mm (coarse positioning arch motion)

[Standard cycle time]

The time required for the fastest operation. Generally, this is a guide for high-speed performance.

Please note that continuous operation at the fastest operation is not possible.

Allowable load moment of inertia at the tip shaft

Allowable load moment of inertia at the tip shaft
0.06kg・m2

The allowable load moment of inertia of the tip axis is the allowable moment of inertia when the tip spline axis of the SCARA robot is converted to the center. The offset amount from the tip axis to the load center should be within the following values. If the position of the center of gravity of the load deviates from the tip axis, it is required to reduce the speed and acceleration as appropriate. The vertical direction refers to a guideline for the amount of offset that the SCARA robot can operate smoothly.

Horizontal directionVertical direction
50mm or less70mm or less