TTA-C3S□(G)-20-15
TTA-C3(G)-20-15

Model specification

ModelAxis ConfigurationEncoder typeMotor typeLead
(mm)
Stroke
(mm)
Speed
(mm/s)
Load Capacity
(kg)
TTA-C3SL(G)-WA-20①-15②-③B④-⑤-⑥-⑦-⑧-⑨-⑩X axisBattery-less
absolute
AC servo
motor
82001 - 600
Y axis81501 - 600
Z axisEquivalent to 2.14100/1501 - 17015
TTA-C3SH(G)-WA-20①-15②-③B④-⑤-⑥-⑦-⑧-⑨-⑩X axisEquivalent to 13.32001 - 600
Y axisEquivalent to 13.31501 - 600
Z axisEquivalent to 5100/1501 - 4007
TTA-C3(G)-WA-20①-15②-③B④-⑤-⑥-⑦-⑧-⑨-⑩X axisPulse motorEquivalent to 242001 - 600
Y axisEquivalent to 241501 - 540
Z axis12100/1501 - 4006

Symbol description ① ② XY-axis option ③ Z-axis stroke ④ Z-axis option ⑤ Standard I/O slot ⑥ ⑦ Expansion I/O slot ⑧ I/O cable length ⑨ Power cable specification ⑩ Option

Actuator specification

HeadingContents
AC servo motorPulse motor
Drive systemBall screw (X, Y-axes: φ12 mm Z-axis: φ10 mm Rolled, C5 equivalent)
Low lead Z-axis: Speed reduces by 1:1.4
using a timing belt High lead X, Y, Z-axes: Speed reduces by 1:1.2
using a timing belt
Ball screw
(X, Y-axes: φ12 mm
Z-axis: φ10 mm
Rolled, C10)
X, Y-axes: Speeds up by
1.5:1 using a timing belt
Accuracy of Repeating Positioning.±0.005mm±0.01mm
Lost motionLow lead X, Y-axes: 0.025 mm
or less Z-axis: 0.02 mm
or less High lead X, Y-axes: 0.04 mm
or less Z-axis: 0.02 mm or less
0.05mm and below
Dynamic allowable momentX-axis:Ma:14.9Nm Mb:14.9Nm Mc:44.3Nm
Y-axis:Ma:14.9Nm Mb:14.9Nm Mc:44.3Nm
Z-axis:Ma:11.5Nm Mb:11.5Nm Mc:24.3Nm
Ambient temperature/humidity0 - 40℃, 85% RH Max (Non-condensing)
Table part loading weight40kg
Body weight29.3kg

Oversea specification

(Note) CE is compatible only with safety category compliant specifications.

Important notes on selection

(1) The maximum acceleration/deceleration differs depending on the load capacity. (Refer to page 4-667) The maximum speed cannot be achieved with the pulse motor at the maximum payload setting. If increase speed, the load capacity will drop. (Refer to page 4-669)
(2) Positioning repeatability is applicable only when the main body temperature is constant. It will not guarantee the absolute accuracy.
(3) The value of the dynamic allowable moment is the value of each axis. When the standard rated life is 5,000 km and the standard load factor is 1.5. (Refer to page 4-671 for the dynamic allowable moment.)
(4) Enter "E" in the expansion I/O slot 1 and 2 of the model item if it is not used.

Return to the page top

Dimension drawing

ME: Mechanical end

SE: Stroke end

(Note) When fixing the work, make sure there is a margin of 2 mm or more for the moving range of the column.

(Note) During home return, the slider moves to the mechanical end. Pay attention to prevent contact between the slider and the surrounding.